Reverse Osmosis Ro Membrane For 2000 Tds Water Filter Assembly Drinking Water Treatment
Industrial Nano Membrane Filter assembly for Drinking Water Treatment Methods
RO and NF membrane have the following differences:
1. Different filtering precision Reverse osmosis can remove the smallest solute with a molecular weight of less than 0.0001 microns. Due to its high filtration accuracy, it can filter out bacteria and various impurities in water. It is generally used in the manufacture of household purified water, industrial ultrapure water and medical ultrapure water. Nanofiltration can remove solutes with a molecular weight of about 0.001 microns, and is used in environments with slightly lower filtration accuracy requirements. It is generally used for water softening, micro-pollution desalination and the manufacture of industrial pure water.
2. Different desalination rates The desalination rate of reverse osmosis technology is 99.5%, which can effectively intercept all dissolved salts and various organic substances with a molecular weight greater than 100, while allowing small molecular groups to pass through. The nanofiltration system adopts the method of cross-flow filtration, and the desalination rate is between 80 and 90%. It is mainly used for the concentration and purification of macromolecular substances.
3. The proportion of "wastewater" produced is different Both reverse osmosis and nanofiltration purify water by pressurizing and electrifying, but the reverse osmosis technology due to the different composition of the membrane, the wastewater produced by reverse osmosis is 1:2-1:3, and the wastewater ratio of nanofiltration is 1:1: 1. In terms of water saving and environmental protection, reverse osmosis technology is more resource-intensive. Compared with nanofiltration technology, it has the advantages of partial removal of monovalent ions, low process osmotic pressure, low operating pressure, and energy saving.
Nanofiltration membranes can retain nanoscale (0.001 micron) substances. The operating range of the nanofiltration membrane is between ultrafiltration and reverse osmosis, the ability to intercept dissolved salts is between 20% and 98%, and the removal rate of soluble monovalent ions is lower than that of high-valent ions. Nanofiltration is generally used to remove surface Organic matter and pigments in water, hardness and radium in groundwater, and partial removal of dissolved salts, extraction and concentration of useful substances in food and pharmaceutical production. The operating pressure of the nanofiltration membrane is generally 3.5-30 bar.
| Model Number | Description | 8040-NF |
| Performance & Test Condition |
The Desalination Rate % | 98% |
| Water Rate GDP | 10200 | |
| The Test pressure | 100psi | |
| Test solution Temperature | 25± 1ºC | |
| Test Solution Concentration NaCl | 2.0-11.0 | |
| Recovery Of Single-Branch Membrane Element | 15% | |
| Feed water SDI | 5 |
- When PH is above 10, the Maximum Temperature of Continuous Operation is 35ºC.
- Under certain conditions, the presence of free chlorine and other oxidants in the water may cause serious membrane damage, which doesn't belong to product warranty range.



FAQ:
Q: How to buy your products?
Q: How to pay?
A: TT and L/C are acceptable and TT will be more appreciated. 30% deposit before producing, 70% balanced against the copy of B/L.
Q: What is the delivery time?
A: Usually within 15days. Also depends on order quantities.
Q: Can the package be customized by our own logo ?
A: Yes, the package can be customized your logo, but the MOQ will be higher for which we can discuss as per the specific orders.
Q: How to install after the products arriving destination?
A: We will provide detailed illustrations to you. And we can also provide guide to your workers how to use it and how to maintain
it.
2000 tds membrane
,ro membrane for 2000 tds
,membrane for 2000 tds water
-
1000 Lph Ss Ro Plant Membrane With Chiller Commercial
1000 lph RO water Treatment Machine Plant / Water Purification RO Plant Reverse osmosis plants require a variety of pre-treatment techniques including softening, dechlorination, and anti-scalent treatment. Following pre-treatment, high levels of pressure send water through a semi-permeable membrane, ... -
Brackish Water High Tds Ro Membrane Element 2400GPD 4-Inch-High Salt Rejection
Brackish Water High Tds Ro Membrane Element 2400GPD 4-Inch-High Salt Rejection The purpose of water treatment is to improve the water quality and make it meet a certain water quality standard. According to different treatment methods, there are many kinds of physical water treatment, chemical water ... -
6000 TDS High Tds Ro Membrane For Water Purifier System Working Up Lp-4040
BW-4040 Working Up 6000TDS Reverse Osmosis RO Membrane for RO Water Purifier System RO membranes, in general, remove 90% or more of the contaminants present in the water, including TDS. When the TDS levels of your water source changes, it will affect the quality of the purified water output from ...