1000 TDS High Flow Ro Membrane 400 Gpd Water Purifier Treatment
Large Flow 400gpd Reverse Osmosis Membrane for RO Water Purifier Water Treatment
RO water removes negligible amounts of calcium from the water but also removes harmful nitrates along with it and we are preventing diseases when we use RO or other water purifiers. Only when the tap water we are supplied is as good as this purified water, should we think about drinking tap water directly.
The product specification
| Model Number | Description | 3013-400 |
| Performance & Test Condition |
The Desalination Rate % | 96% |
| Water Rate GDP | 400 | |
| The Test pressure | 100psi | |
| Test solution Temperature | 25± 1ºC | |
| Test Solution Concentration NaCl | 500ppm | |
| Test solution pH value | 6.5-7.5 | |
| Recovery Of Single-Branch Membrane Element | 50%±5 | |
| Feed water SDI | ≤5 |
SPECIFICATION:
| Model | Stable rejection rate(%) | average permeate flowGPD(m3/d) | test condition | ||
| operation pressure psi(Mpa) | test liquid NaCl(ppm) | recovery rate (%) | |||
| 1812-BW50 | 97 | 50(0.19) | 60(0.41) | 250 | 15 |
| 1812-BW75 | 97 | 75(0.28) | 60(0.41) | 250 | 15 |
| 1812-BW100 | 97 | 100(0.38) | 60(0.41) | 250 | 15 |
| 2012-150 | 95 | 150(0.57) | 70(0.5) | 500 | 15 |
| 2012-200 | 95 | 200(0.76) | 70(0.5) | 500 | 15 |
| 2812-300 | 97 | 300(1.14) | 70(0.5) | 500 | 50 |
| 2812-400 | 95 | 400(1.52) | 70(0.5) | 500 | 50 |
| 3013-400 | 95 | 400(1.52) | 70(0.5) | 500 | 50 |
| 3013-600 | 95 | 600(2.28) | 70(0.5) | 500 | 50 |
| 3013-800 | 95 | 800(3.04) | 100(0.68) | 500 | 50 |
Note:1. The Max. continous operation temperature is 35ºC when PH rate over 10.
2. In certain conditions,if would cause membrane breakage if the free chlorine or the other oxidant in feedwater.The production quality guarantee range is notincluded membrane breakage by oxiadation.

3013-400: A:13.0inch B:3.0inch C:0.68inch D:0.75inch E:10.0inch
RO membrane continues to increase in demand with the growth of the water treatment sector. However, fouling and scaling are its major drawbacks. Fouling occurs in both cellulose-based and thin-film composite membranes. So we have professional R&D and after sale service for our customers.

FAQ:
A: We have NSF,RoHS, C, ISO9001, OHSAS18001, ISO14001 Certifications.
1000 TDS High Flow Ro Membranes
,1000 TDS High Flow Ro Membranes 400 gpd
,1000 TDS ro purifier membranes
-
Liquid Polyamide Ro Membrane Filter 75 Gpd 1809 NSF RoHS
Custom Size 1809-75G Reverse Osmosis Element for RO Water Filter There are better choice from competitiors' similar products because of the specifications of being safer(RO purified water is conformed to drinking water safety rules and USEPA Drinking Water Standard),better taste(RO membranes move ... -
800GPD Ro Membrane Element Salt Water Reverse Osmosis Membrane Ultrafiltration
3313-800GPD Anti-Pollution Water Purifier RO Membrane for Water Treatment The invention relates to an anti-pollution composite reverse osmosis membrane and a preparation method thereof. According to the invention, an epoxy group at the terminal of PEG is utilized to react with the residual free ... -
5000 High TDS RO Membrane Manufacturer Low Pressure Water Purifier
5000TDS Low Pressure Water Purifier of Reverse Osmosis RO Membrane Element The three main indicators of the performance of reverse osmosis membrane elements are the production water flux, the salt rejection rate and the membrane pressure drop, which are mainly characterized by the specific feed ...