1000 GPD Commercial Ro Membrane High Flow Reverse Osmosis Membranes For Water Treatment
Commercial High Flow 3313-1000GPD Reverse Osmosis RO Membrane for Water Treatment
Due to the influence of water quality and other factors, the specific replacement time depends on whether the daily maintenance and cleaning of the reverse osmosis membrane are timely, and the water quality will determine how long the membrane can be used. With the continuous development of industry, the phenomenon of water pollution is becoming more and more serious, which has caused great harm to people's survival. More and more industrial production and domestic water manufacturers choose to use industrial pure water equipment to improve water quality. In the process of water equipment, due to water impurities, it will slowly accumulate on the surface of the reverse osmosis membrane, which will affect the use of the equipment for a long time.
If you need filtered water, a reverse osmosis system is a good solution. Install a reverse osmosis system under your kitchen sink to supply purified water. You can do it yourself in less than 2 hours.
RO system membrane is made of the sedi-permeable membrane with the 0.1mm filtration precision for separating and removing the dissolved solids, organics, bacteria etc. According to the water output capacity, the different large flow membrane is available as follows: 300G, 400G,500G,600G,700G,800G,1000G.
Performance and test conditions
| model | Stable rejection rate(%) | average permeate flowGPD(m3/d) | test condition | ||
| operation pressure psi(Mpa) | test liquid NaCl(ppm) | recovery rate (%) | |||
| 3012-300 | 97 | 300(1.14) | 90(0.61) | 500 | 50 |
| 3013-400 | 95 | 400(1.52) | 90(0.61) | 500 | 50 |
| 3013-600 | 95 | 600(2.28) | 100(0.7) | 500 | 50 |
| 3013-800 | 95 | 800(3.04) | 100(0.7) | 500 | 50 |
| 3313-1000 | 95 | 1000(3.79) | 100(0.7) | 500 | 50 |
Note: Single membrane permeate flow change in the range of ±15%
Test Conditions
Test Pressure 100psi( 0.7Mpa)
Temperature 25ºC
Concentration of Testing Solution (NaCl) 500ppm
Testing Solution PH 2-11
Note:
1. The Max. continous operation temperature is 35ºC when PH rate over 10.
2. In certain conditions,if would cause membrane breakage if the free chlorine or the other oxidant in feedwater.The production quality guarantee range is notincluded membrane breakage by oxiadation.
Dimension of Membrane Element

3013-1000: A:13.0inch B:3.0inch C:0.68inch D:0.75inch E:11.5inch
High-flow, high-rejection, low-energy reverse osmosis (RO) membrane elements are making desalination a more economical choice than ever before by reducing the cost of produ-cing potable water by up to 20%.


FAQ:
A: We have NSF,RoHS, C, ISO9001, OHSAS18001, ISO14001 Certifications.
high flow reverse osmosis membrane
,reverse osmosis membranes for water treatment
,reverse osmosis 1000 gpd
-
Ro Reverse Osmosis Element 400 Gpd Membrane High Rejection 96
400gpd Water Filter RO Membrane GT-3012-400 for Reverse Osmosis Water Purifier System The anti-pollution reverse osmosis membrane is a suitable reverse osmosis membrane developed for the influent water environment with poor water quality. Compared with ordinary reverse osmosis membrane elements, the ... -
Home Reverse Osmosis Element Ultra Low Pressure Ro Membrane 500 Gpd
500GPD Water Purifier of Reverse Osmosis RO Membrane for RO Water Treatment The anti-pollution reverse osmosis membrane has a certain anti-pollution performance, the speed of fouling is much smaller than that of the ordinary reverse osmosis membrane, and the quasi resistance is small, so the energy ... -
4040 NF RO Membrane Nanofiltration In Wastewater Treatment 1800GDP
4040 Nanofiltration Membrane Water Treatment Membrane for Water Filtration System Model Number Description 4040-NF Performance & Test Condition The Desalination Rate % 98% Water Rate GDP 1800 The Test pressure 100psi Test solution Temperature 25± 1ºC Test Solution Concentration NaCl 2.0-11.0 ...