Filmtec 75 Gpd Domestic Ro Membrane 1812-75 Gpd Reverse Osmosis Element Water Filter Cartridges
Filmtec Water Filter Cartridges 1812 75gpd Reverse Osmosis RO Membrane
Reverse osmosis means that when a pressure greater than the osmotic pressure is applied to the concentrated solution side, the solvent in the concentrated solution will flow to the dilute solution, and the flow direction of this solvent is opposite to the original penetration direction. This process is called reverse osmosis; This principle is used in the field of liquid separation, purification, impurity removal, and treatment of liquid substances.
Performance
Performance and test conditions
| Model | Average Permeate Flow (gpd) | Stable Desalination Rate (%) | Minimum Desalination Rate (%) |
| NCM 1812-75 | 75 | 97 | 96 |
Note: Single membrane permeate flow change in the range of ±15%
Operating Limits:
| Membrane type | Polyamide thin-film composite |
| Maximun Operating Pressure | 70psi |
| Maximum Operating Temperature73.4 | °F(25C°) |
| Maximun Feed Water TDS25 | 250ppm |
| Maximum sdi (15min) | 5.0 |
| Maximum Turbidity | 1.0 NTU |
| Maximum Chlorine Concentration | <0.1mg/L |
| Operating PH range | 2~10 |
Membrane Dimention

1812-75: A:11.74inch B:1.8inch C:0.68inch D:0.87inch E:10.0inch
1.When PH is above 10, the Maximum Temperature of Continuous Operation is 35ºC.
2. Under certain conditions, the presence of free chlorine and other oxidants in the water may cause serious membrane damage, which doesn't belong to product warranty range.
Stable Salt Rejection Water Treatment Filter
| Model | Purification flux | Average flow rate | specification and dimension | Matched RO housing |
| 1812-50 | 50GPD | 0.13 L/min | 45×298mm | Type 1812 RO housing |
| 1812-75 | 75GPD | 0.20 L/min | 45×298mm | |
| 2012-100 | 100GPD | 0.26 L/min | 47×298mm | Type 2012 RO housing |
| 2012-125 | 125GPD | 0.33 L/min | 47×298mm | |
| 2012-150 | 150GPD | 0.40 L/min | 47×298mm | |
| 2812-200 | 200GPD | 0.52 L/min | 68×298mm | Type 2812 RO housing |
| 3012-300 | 300GPD | 0.78 L/min | 73×298mm | Type 3012 RO housing |
| 3012-400 | 400GPD | 1.00 L/min | 73×298mm | |
| 3013-400 | 400GPD | 1.00 L/min | 67.8×333mm | Type 3013 RO housing |
| 3013-600 | 600GPD | 1.56 L/min | 67.8×333mm | |
| 3013-800 | 800GPD | 2.1L/min | 67.8×333mm | |
| 3013-1000 | 1000GPD | 2.63L/min |
67.8×333mm |
Our Service:
Pre-sale service
1.We have full stock and can deliver within short time.
2.OEM and ODM order are accepted, Any kind of logo printing or design is available.
3.Good Quality + Factory Price + Quick Response + Reliable Service, is what we are trying to offer.
4.All of our products are produced by our professional workers and we have our high-work-effect foreign trade team, you can totally believe our service.
After you choose
1. We will count cheapest shipping cost and make invoice to you at once.
2. Check quality again, then send out to you within 7 working days after your payment
3. Email you the tracking No., and help to chase the parcels until it arrive you.
After-sale service
1.We are very glad that customers give us some suggestion for price and products.
2.If you have any question,please contact us freely by E-mail or Telephone.

FAQ:
Q1: What can you buy from us?
A1: Most kinds of household RO machine and its accessories, industrial reverse osmosis equipment, industrial softening equipment, precision control and related accessories
Q2: How can we guarantee quality?
A1: We have a pre-production sample before mass production&final Inspection before shipment; Our products are certified.And we can supply SGS,ISO9001,CE certification.
Q3: How to make payment ?
A3: We accept payment by L/C, T/T, Western Union, Money Gram, Trade Assurance, etc
Q4: Can you provide brand customization and packaging customization?
A4: Yes, OEM and ODM are available based your demand.
filmtec reverse osmosis membranes
,filmtec membrane 75 gpd
,filmtec reverse osmosis element
-
10500GPD Water Purifier RO Membrane for Industrial Reverse Osmosis Plant Large Scale Treatment
10500GPD Water Purifier RO Membrane for Industrial Reverse Osmosis Plant Large Scale Treatment An Industrial Reverse Osmosis (RO) Plant is a water treatment plant useful to eliminate hazardous chemicals and impurities from the water through reverse osmosis technique. Reverse osmosis process purifies ... -
4040 NF RO Membrane Nanofiltration In Wastewater Treatment 1800GDP
4040 Nanofiltration Membrane Water Treatment Membrane for Water Filtration System Model Number Description 4040-NF Performance & Test Condition The Desalination Rate % 98% Water Rate GDP 1800 The Test pressure 100psi Test solution Temperature 25± 1ºC Test Solution Concentration NaCl 2.0-11.0 ... -
Reverse Osmosis Ro Membrane For 2000 Tds Water Filter Assembly Drinking Water Treatment
Industrial Nano Membrane Filter assembly for Drinking Water Treatment Methods RO and NF membrane have the following differences: 1. Different filtering precision Reverse osmosis can remove the smallest solute with a molecular weight of less than 0.0001 microns. Due to its high filtration accuracy, ...